SUGIYAMA ELECTRIC SYSTEM INC.

  1. HOME
  2. Products guide
  3. Products information
  4. PS-101T

PS-101T Malfunction detector

PS-101T Malfunction detector

Description

PS-101T is a safety device of one channel used for the exhaust confirmation of the miss feed detection or the product.

Features

  • The timing signal from the press, both the limit switch and the adjacent switch are also possible.
  • Two functions are installed in the Passage detection unit.
  • The timing signal circuit is equipped with the timing timer function.

Dimensions

PS-101T

PS-101T

PS-101T

Specification

Detection channels 1
Detection mode Passage (modes1,2)
Voltage of detection circuit DC12V
Timing mode Timer timing (25 ms ~ 2.5 s)
Voltage of timing circuit DC12V
Stop output circuit Relay output AC200 V 2 A (max.)
Stop output delay time Approx. 25 ms
Power supply voltage AC100 V ~ 200 V
Temperature 0 to 55 degree C
Dimensions(WHD) 170 * 49 * 146 mm (An umbo is not included.)
Weight 1.9kg(inc. mounting bracket)
Power consumption Approx. 7 VA
Attachments
  • Output cable (Standard: 5 m)
  • US-1 1(red)
  • Instruction manual

    Optional sensor

    Click on image for more information.

    Light sensor (OS series)
    Light sensor (OS series)
    Light sensor (LS series)
    Light sensor (LS series)
    Loop sensor
    Loop sensor
    Spring sensor
    Spring sensor
    Acoustic sensor
    Acoustic sensor