PS-104F Malfunction detector
Description
PS-104F is a malfunction detection device with four channels of the contact detection method for the press machine. The jack method is used for detection-input terminals of all channels in front of the panel.
Features
- With the toggle switch, the input polarity of all channels is immediately switchable to A or B.
- If the timing signal is input, CH1 turns to the synchronous detection method.
- The power supply of an electronic sensor can be provided from the 3-contact jack to CH1.
- Remote resetting is available by connecting the external reset.
- Turning off the power supply switch of PS-104F can prohibit the press machine from continuously operating if the continuous inhibition output is connected.
- The stop outputs are two systems (CH1/2 and CH3/4).
Dimensions
PS-104F
Back view
Specification
| Detection channels | 4 |
| Detection mode | Detect the touch or break (The rotation and the synchronization of the press can be taken in CH1. ) |
| Stop output circuit | Relay output AC200 V 2 A (max.) |
| Stop output delay time | Approx. 5 mS |
| Power supply voltage | AC100 ~ 200 V |
| Temperature | 0 to 55 degree C (No sudden temperature change during the use.) |
| Dimensions(WHD) | 200 * 68.5 * 184 mm (An umbo is not included.) |
| Weight | 2.0 kg(inc. mounting brackets.) |
| Power consumption | Approx. 7 VA (max.) |
| Attachments |
|
Optional sensor
Click on image for more information.