PS-321 Cutting counter
Description
Cutting counter PS-321 is designed to produce and output control signals from the Count input signal. The control signals are produced based on the Count cycle.
Features
- Three forms of Count modes
- You can select three forms of Count modes by pushing buttons on the front panel.
- In the Count mode 1, two channels operate independently.
- In the Count mode 2 and 3, output is controlled by two setting values for one Counter.
- Easy-to-change Count values by panel operation
- Without applying Count signals, you can change the Count value by the front panel operation.
- Prohibition of unnecessary operations
- PS-321 has the operation prohibition function to prevent errors in operations.
- Independent SSR and open collector output
- Each channel has SSR and open collector output. Four outputs or less are available.
- Variety of output forms
- You can select out of 4 output forms in the Count mode 1 and 15 forms in the Count mode 2/3.
- You can select them by the device setting.SSR and open collector can be set separately.
- Counter control functions such as Count interruption and Count reset
- In the Count mode 2/3, the Count input 2 can be also utilized as a Counter control input.
- Built-in SSR for output
- ACSSR or DCSSR for output can be installed. To replace SSRs, remove the back panel. Use the SSR specified by Sugiyama Electric System Inc.
- Remote control available (OPTION)
- Most operations can be remotely controlled by commands from such devices as the programmable controller. However, optional settings are required.
Dimensions
PS-321
Specification
| Count digit | 3 digit |
| Max Count speed | 200 CPS |
| Count channel number | 2 (Count mode 1) 1 (Count mode 2, 3) |
| Output form | 4 (Count mode 1) 5 (Count mode 2, 3) |
| DCSSR | DC30 V 500 mA max. |
| ACSSR | AC240 V 1 A max. |
| Open collector | DC30 V / 100 mA max. |
| Power supply voltage | AC100 ~ 240V +/-10% 50/60Hz |
| Power supply Consumption | 15 VA max. |
| Weight | Body 2.8 Kg (inc. mounting brackets) |
| Ambient operating temperature | 0 to 55 degree C No sudden temperature change during the use. |
| Dimensions(WHD) | 200 * 98.5 * 184 mm (An umbo is not included.) |
| Attachments | Output cable (Standard: 5 m) Instruction manual ACSSR (It is possible to exchange it for DCSSR.) *It has installed it internally. |