SUGIYAMA ELECTRIC SYSTEM INC.

  1. HOME
  2. Products guide
  3. Products information
  4. PS-482/484/488

PS-482/484/488 Slug Detector[ ※Specification change after March 1, 2025 ]

Description

The Slug Detectors PS-482/484/488 are designed for detecting slugs, double piles driving, and so on, during automatic press working and for outputting stop signal to the press in case of abnormalities.
It reads a signal from Eddy current proximity sensor installed on the mold for the press and calculate the displacement by a microcomputer. If the displacement exceeds the limit, it outputs the stop signal to the press.
Since Ethernet is supported, the PS-482/484/488 can be connected to personal computer (PC) and PLC.

Features

The PS-482/484/488 have the following additional features together with those of our PS-462/464.

  • Added functions helpful for detection
    • - The LCD panel displays sensor waveforms.
    • - Sensors can be connected up to eight (8) channels.(PS-488)
    • - Unevenness calculation and multiple detection are available.
  • Functions helpful for production control
    • - Up to 99 patterns can be Stored.
    • - Up to 1000 error histories and displacement for four strokes before and after the error can be saved.
    • - Patterns can be recalled by ID tags. (Options)
  • Ethernet supported
    • - The contents of setting can be displayed in HTML format.
    • - UDP protocol and Telnet protocol enable various settings and operations.
    • - FTP protocol enables to output the displacement data during press working.

Panel specifications (March 1, 2025 or later)

*The changes will be implemented sequentially from shipments made after March 1, 2025.

PS-48x panel

Dimensions

PS-482/484/488

PS-482/484/488

PS-48x

(touch panel type)ps-482/484/488

Back view

PS-48x

Specification

Detect
Channels 2CH (PS-482) / 4CH (PS-484) / 8CH (PS-488)
Resolution 1μm or 0.1μm
Max. limit value 200μm or 20.0μm
Detect mode Internal timing, External timing
Max. SPM 4000SPM
Sensor
Sensor Installation distance
(at B.D.C.)
0.7 to 1.5 mm
Length of sensor cable 1 to 10m (Standard 3m)
Temperature 0 to 55°C
Input/Output
Power supply voltage
100 to 240 VAC ±10%,50/60Hz (Max. 40VA)
Relay output EMG Stop, TDC Stop, READY,ALARM
(Max. 250VAC / 30VDC 3.0A)
External input ON/OFF, RESET, LOCK,
TIMING (T1, T2, T3)
Open collector output AUX (5 to 24 VDC 100mA)
Ethernet
Physical layer 10BASE-T/100BASE-TX
Protocol IPv4
UDP, DHCP, HTTP, Telnet, FTP
Others
Dimensions of the body 200(W)× 98.5(H)×190(D) excluding projections
Weight 3.0 kgW (inc. mounting bracket)
Temperature 0 to 55°C (must not be sudden change while using it)
Humidity 35 to 85%RH (no dew condensation allowed)

Sensor heads

Only the mechanical dimentions are different,the electric characteristic are all the same.

Click on image for more information.

PS-4013
PS-4013
PS-4014
PS-4014
PS-4018
PS-4018
PS-4020
PS-4020
PS-4024
PS-4024
PS-4025
PS-4025
PS-4026
PS-4026
PS-4027
PS-4027
PS-4028
PS-4028
PS-4029
PS-4029
PS-4031
PS-4031
PS-4032
PS-4032
PS-4033
PS-4033
PS-4034
PS-4034

Sensor Cable Series of 243297

The colors of the sensor cable are blue, red, yellow, and white.

blue red white yellow
blue red white yellow

Sensor Cable Series of 243297 Order codes