PS-682 Malfunction detector[ ※Specification change after August 1, 2025 ]
Description
The Malfunction Detector “PS-682” detects the status of automatic pressing, such
as
material shortage, material feeding, discharge of processed goods, and outputs a stop signal
to the
press in case of trouble.
Several functions using timing signal, such as counting, calculation of work rate, error
recording,
will assist you in production control.
PS-682 supports Ethernet to connect with a personal computer or PLC.
It employs DIN connector and remotely operable light sensor can be used. Since a voltage of
12V or
24V is outputted, a 24 V sensor can be used as well as conventional light sensor.
Features
While the features of our “PS-661/662” remain as they are, the following features are added.- Improvement of operability by LCD
- - Detecting method can be freely set for all channels.
- - Total counter, preset counter and setting values can be seen at a glance.
- - Work rate and SPM are indicated.
- - Allowance angle is indicated (patent pending).
- - Displaying the number of counts of extraction.
- - Displaying an error information.
- Provided with helpful functions for production control
- - Up to 99 patterns can be registered.(Pattern name: 12 characters)
- - A record of up to 500 errors and counter outputs can be saved.
- - Pattern changes can be made by sending binary data from the PLC. (Optional)
- Ethernet supported
- - The setting or the like in HTML format can be checked.
- - The saved record can be downloaded in CSV format.
- - Various types of setting and operation are available through Telnet communication. (communicate via PLC)
- Enhancement of sensor feature
- - The sensitivity of OS series can be adjusted by addition of communication line.
- - Detection will be ON automatically or it gives stop output when it gets sensor input while detection is ON.
- - Various types of sensor can be used, because a voltage of 12V or 24V is outputted.
Panel specifications (August 1, 2025 or later)
*The changes will be implemented sequentially from shipments made after August 1, 2025.
Specification
| Item | ||
|---|---|---|
| Detect | Channels | 6Channels |
| Detect mode | Touch, Synchronization, Passage, Feed, Extraction, Timer, Counting feed | |
| Power source for sensors (by the total) | 12VDC (Max. 500mA) 24VDC (Max. 200mA) |
|
| Output response time | Max. 10 ms | |
| Counter | Digits | Total Counter:6 Preset Counter:6 |
| Output response time | Max. 10ms | |
| Input/output | Power supply voltage | 100-240VAC ± 10%、50/60Hz(Max. 40VA) |
| Relay output | EMG Stop, TDC Stop, READY, ALARM (Max. 250 VAC / 30 VAC 3.0A) |
|
| External input | ON/OFF, RESET, LOCK,TIMING (T1, T2, T3) | |
| Sensor input | No-voltage contact 3-wire NPN open collector |
|
| Ethernet | Physical layer | 10BASE-T/100BASE-TX |
| Protocol | IPv4 UDP、DHCP、HTTP |
|
| Others | Temperature | 0 to 55°C (must not be sudden change while using it) |
| Humidity | 35 to 85%RH (no dew condensation allowed) | |
| Dimensions of the body | 200(W) × 120(H) × 190(D) excluding projections | |
| Weight | 3.4 kgW (inc. mounting bracket) | |
DIN-plug conversion cable
PS-682 is adopting new connector differ from conventional product.
It is necessary DIN-plug conversion cable to PS-682 to use the sensors used for conventional
product.DIN-plug conversion cable is provided when select 「01」 at the order code of
accessory of
sensor of PS-682.It is possible to purchase only DIN-plug conversion cable.The color and
cable
length of DINP-1J are fixed.
If you need to change the color or cable length of DINP-1J, please place an order
by USE-DE series.
Optional sensor
Click on image for more information.