Order codes | Leaflet![]() |
Functions equivalent to PS-333
|
|
LCD panel provides enhanced operability
|
|
Detection by sensor (optional)
|
|
Provided with helpful functions for production control
|
|
Ethernet supported
|
Item | Specifications | |
Count | Max. step | 1000 |
Output | Channels | 8 Channels |
Rating | SSR for both AC load and DC load 75 to 240 VAC / 5 to 24 VDC Max. 1.0A (Total of all channels 5.0A) |
|
Detect (Optional) |
Sensor detection | Forward end, Backward end |
Sensor input | No-voltage contact DC 2-wire sensor |
|
Power source for sensors | 24VDC (Max.200mA) | |
Input / output | Power source voltage | 1100 to 240 VAC ±10%, 50/60 Hz (Max. 40 VA) |
Relay output | EMG Stop, READY, ALARM (Max. 250 VAC / 30 VDC 3.0 A) |
|
External input (NPN) |
Count ON/OFF, Count RESET, LOCK, RESERVED TIMING (T1, T2, TD) |
|
Open collector output | Aux output (CH1, CH2) (5 to 24 VDC 100mA) |
|
Ethernet | Physical layer | 10BASE-T/100BASE-TX |
Protocol | IPv4 UDP, DHCP, HTTP, Telnet |
|
Construction | Dimensions of the body | 200(W) × 98.5(H) × 190(D) excluding projections |
Weight | 3.3 kgW (inc. mounting bracket) | |
Environment | Temperature | 0 to 50 °C (must not be sudden change while using it) |
Humidity | 35 to 85 %RH (no dew condensation allowed) |