PS-474P/478P Slug Detector
Description
The Slug Detector "PS-474P/478P" combines advanced detection capabilities with excellent usability, solving challenges that were previously considered unsolvable.
Furthermore, by adding up to 8 channels, a revamped waveform display, and IoT connectivity, it makes "detection" more powerful and smarter.
Features
The PS-474P/478P have the following additional features together with those of our PS-474.
- Added functions helpful for detection
- Sensors can be connected up to eight (8) channels.(PS-478P)
- Waveforms can be displayed in an overlaid view or a difference view.
- Unevenness calculation and multiple detection are available.
- Functions helpful for production control
- Up to 99 patterns can be Stored.(Pattern name: 12 characters)
- Up to 8,000 history records and approximately 30 million displacement data can be stored in the product itself.
- Pattern changes can be made by sending binary data from the PLC.(Optional)
- Ethernet supported
- The contents of setting can be displayed in HTML format.
- UDP protocol enable various settings and operations.
- By connecting to a PLC, displacement data can be retrieved in real-time
Specification
| Item | ||
|---|---|---|
| Detect | Channels | 4CH (PS-474P) / 8CH (PS-478P) |
| Resolution | 1μm or 0.1μm (Export Specification:0.5μm(standard value fixed)) |
|
| Max. limit value | 200μm or 20.0μm | |
| Detect mode | Internal timing , External timing | |
| Max. SPM | 4000SPM | |
| Sensor | Sensor Installation distance (at B.D.C.) |
0.7 to 1.5mm |
| Length of sensor cable | 1 to 10m(Standard 3m) | |
| Temperature | 0 to 55°C | |
| Record・Storage | Number of record labels | 8000 data |
| Number of record strokes (Approx.) | 30 million data | |
| Number of record waveforms | 8 waveforms | |
| Pattern | 99 patterns ( 12 chars/name ) | |
| Input/Output | Power supply voltage | 100 to 240 VAC ±10%,50/60Hz (Max. 40VA) |
| Relay output | EMG Stop, TDC Stop, READY, ALARM (Max. 250VAC / 30VDC 3.0A) |
|
| External input | ON/OFF, RESET, LOCK, SPARE TIMING (T1, T2, T3, T4) |
|
| Open collector output | AUX (5 to 24 VDC 100mA) | |
| Ethernet | Physical layer | 10BASE-T/100BASE-TX |
| Protocol | IPv4 UDP, DHCP, HTTP |
|
| Others | Dimensions of the body | 200(W)× 200(H)×190(D) excluding projections |
| Display Resolution | 800×480 | |
| Weight | 3.0 kgW (Only the main body) | |
| Temperature | 0 to 55°C (must not be sudden change while using it) | |
| Humidity | 35 to 85%RH (no dew condensation allowed) | |
Sensor heads
We stock a wide range of sensor heads to accommodate various types of dies.
Click on image for more information.
Sensor Cable Series of 243297
The colors of the sensor cable are blue, red, yellow, and white.
| blue | red | white | yellow |
|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
Pattern change
[Display a photo of the PS-474P/478P with the ID reader attached here.]
When changing patterns using an ID tag
PC/When changing patterns using a PC or PLC
Displacement and waveform data output
It can transmit displacement or waveform data recorded during the press process to a PC or PLC.
Data is transmitted in hexadecimal.
For example, displacement data is displayed at x10 magnification, and for each stroke, 2 bytes of displacement data and 2 bytes of limit values are transmitted per channel.
For a resolution of 1 µm : -2000 to 2000
For a resolution of 0.1 µm : -200 to 200
(ex:+10um→100(x10)→0x0064,-10um→-100(x10)→0xFF9C)
Comparison with PS-474
Display on a web browser
You can view and save the LCD screen image via a web browser.
Waveform display and CSV saving
You can display recorded sensor waveforms and save them in CSV format.